Aerotec Pte. Ltd.  Tel: +65 6749 4749  Fax: +65 6749 5567  E-mail: sales@aerotec.com.sg  Emergency: +65 9169 9990
  BRIFE OF OUR PRODUCTS
--

Compressor
-----------------------------------------
--
Heater
-----------------------------------------
--
Marine Air Conditioner
-----------------------------------------
--
Ducting & Accessories
-----------------------------------------
--
--
Grille, Diffuser, Louver
-----------------------------------------
--
Outfitting
-----------------------------------------
--
Diffuser box
-----------------------------------------

--

Marine Fan
-----------------------------------------
--
--
Mist eliminator
-----------------------------------------
--
Deck machinery
-----------------------------------------
--
Coating & sandblasting
machniery

-----------------------------------------
--
Duct forming machniery
-----------------------------------------
--
Sewage treatment and bilge
device

-----------------------------------------
--
 Switchboard
-----------------------------------------
--
 Busbar
-----------------------------------------
--
 Cable Support System
-----------------------------------------
--
 Shipboard and Offshore Cables
-----------------------------------------
--
 Transformer
-----------------------------------------
--
 NOZZLES
-----------------------------------------

 

Flame Retardant Power Cable
TPY,FA-TPY;TPYC,FA-TPYC; TPYCY,FA-TPYCY
Conductor: Tinned copper annealed stranded copper (STC) Class 2
Insulation: Ethylene propylene rubber (EPR)
Sheath: Polyvinyl chloride (PVC)
Armor: Galvernized steel wire braid (GSWB); Paint in white is needed for TPYC and FA-TPYC
Outer Sheath: Polyvinyl chloride (PVC)
Operating temperature: 90℃


Low Voltage Shipboard Power Cable
Common Shield Flame Retardant Power Cable
TPYCS,FA-TPYCS
TPYCYS, FA-TPYCYS
Insulation: Ethylene propylene rubber (EPR)
Sheath: Polyvinyl chloride (PVC)
Common shield: Tinned copper wire braid (TCWB)
Conductor: Tinned copper annealed stranded
copper (STC) Class 2
Armor: Galvernized steel wire braid (GSWB); Paint in
white is needed for TPYCS and FA-TPYCS
Outer Sheath: Polyvinyl chloride (PVC)
Operating temperature: 90℃


MV Shipboard Power Cable--Single Core
EPR Insulated PVC Sheathed Tinned Copper Wire Braid Armor Cable-Flame Retardant
Flame retardant MV cable
SPYCB FA-SPYCB
SPYCBY FA-SPYCBY
Rated Voltage
● 3.6/6(7.2)kV
● 6/10(12)kV
● 8.7/15(17.5)kV
Operating temperature: 90℃
Insulation: Ethylene propylene rubber (EPR)
Sheath: Polyvinyl chloride (PVC)
Conductor: Tinned copper annealed stranded copper (STC) Class 2
Conductor screen: Extruded semi conductive layer
Design
Flame retardant
Flame retardant for "FA" type
Application
Fixed installation for shipboard medium
voltage power systems.


阻燃电力电缆
TPY、FA-TPY;TPYC、FA-TPYC; TPYCY、FA-TPYCY
导体:镀锡铜退火铜绞线(STC)2级
绝缘材料:乙丙橡胶(EPR)
护套:聚氯乙烯(PVC)
铠装:镀锌钢丝编织层(GSWB);TPYC和FA-TPYC需要涂成白色。
外护套:聚氯乙烯(PVC)
工作温度:90℃


低压船用电力电缆
通用屏蔽阻燃电力电缆
TPYCS、FA-TPYCS
TPYCYS、FA-TPYCYS
绝缘材料:乙丙橡胶(EPR)
护套:聚氯乙烯(PVC)
通用屏蔽:镀锌铜丝编织层(TCWB)
导体:镀锡铜退火铜绞线(STC)2级
铠装:镀锌钢丝编织层(GSWB);TPYCS和FA-TPYCS需要涂成白色。
外护套:聚氯乙烯(PVC)
工作温度:90℃


中压(MV)船用电力电缆——单芯
EPR绝缘PVC护套镀锡铜绞线铠装电缆——阻燃
阻燃MV电缆
SPYCB FA-SPYCB
SPYCBY FA-SPYCBY
额定电压
● 3.6/6(7.2)kV
● 6/10(12)kV
● 8.7/15(17.5)kV
工作温度:90℃
绝缘材料:乙丙橡胶(EPR)
护套:聚氯乙烯(PVC)
导体:镀锡铜退火铜绞线(STC)2级
导体屏蔽:挤出半导体层
设计
阻燃剂
“FA”型使用的阻燃剂
应用
船舶中压电力系统的固定设备

 

Aerotec Pte. Ltd. Address: No. 10 Ubi Crescent #04-98 UBI TECHPARK Lobby E, Singapore 408564 Tel: +65 6749 4749 Fax: +65 6749 5567
亚拓(私人)有限公司 乌美湾10号 乌美科技园 #04-98,新加坡邮区408564 电话:+65 6749 4749 传真:+65 6749 5567